Blood Pressure Sensor

The measuring principle of the blood pressure sensor is to adjust the inflation volume of the cuff to the upper arm, change the pressure, and the blood flow through the blood vessels has a certain oscillation wave, which is received by the sensor and converted into electrical signals; According to the change of the oscillating wave, the air pressure and fluctuation detected by the sensor will also change. The time of maximum fluctuation is selected as the reference point. Based on this point, the fluctuation point of a certain value is found forward as systolic pressure, and the fluctuation point of a certain value is found backward as diastolic pressure.

Distance Sensor

The Distance sensor consists of two parts: transmitter and receiver; The working principle is that the propagation speed of light is much faster than that of sound waves. Therefore,it can be assumed that the propagation time of light is 0. The transmitter sends an infrared light signal to inform the receiver the beginning time of ultrasonic wave and sends the ultrasonic wave, the receiver receives the light signal and start to record the beginning time and counts until it receives the ultrasonic signal ,so as to calculate the time used for ultrasonic propagation. Finally, according to the formula “distance=speed × time ”to calculate the distance between transmitter and receiver. There is a screw hole (M6 thread) on the side of the Distance sensor, which can be used to fix the sensor on a suitable device.

EKG Sensor

EKG Sensor is used detect the micro voltage produced by heartbeat. Two wires are used to measure the change of voltage and convert them into electric signal. The change of voltage is displayed in wave form. There is a screw hole (M6 thread) on the side of the Distance sensor, which can be used to fix the sensor on a suitable device.

Respiration Sensor

There is a screen placed in the center of transparent part in the front of Respiration Sensor. The blow-in air will form pressure difference behind the screen. The tubes in front of and behind the screen transfer it to pressure sensor. Stronger the air flow passes through screen, bigger pressure difference will be formed. Sensor can transfer the pressure value into velocity of air flow. The air flow velocity will be transfer to volume by the formula designed in software.

ORP Sensor

ORP Sensor is used to measure the reduction solution redox potential (ORP). The front side of sensor is ORP Sensor electrode. It is a kind of electrode that can absorb and release electrons on its sensitive layer. The sensitive layer is a kind of inert metal. It is normally made of platinum and gold.

SO2 Sensor

The working principle of SO2 Sensor is electrochemistry. When SO2 gets inside of electrode, electrical potential and current will be generated according to the working principle. Sensor collects those data and display the concentration of SO2 according to the relationship between SO2 and electrical potential and current.

Nitrite Ion Sensor

The sensor is designed with ion selective electrode. It is a kind of electrochemistry sensor which measures ion activity and concentration in solution using membrane potential. When it touches the solution with ion to be measured, membrane potential will be generated between its membrane and solution. Ion selective electrode is also called membrane electrode. There is a layer of special electrode membrane on the electrode which response to specific ion. The relationship between potential of electrode membrane and ion to be measured compliance with Nernst formula. The circuit of sensor converts potential to analog signal.

Alcohol Gas Sensor

The sensing component of Alcohol Gas Sensor is made of the metallic oxide semiconductor on the aluminum oxide plate. When there is alcohol gas exists in the environment, conductivity of sensor will be increasing with concentration of alcohol gas. The sensor converts changing of conductivity into concentration of alcohol gas.

Chlorine Gas Sensor

The working principle of Chlorine Gas Sensor is measuring concentration of chlorine by using electrochemistry. The probe consists of electrode and electrolyte. The electrolyte is separated by a selective gas-permeable membrane. The gas diffusing in sensor occurs redox reaction on the surface of electrode. Current is generated in the electrode. The value of current is corresponding to the concentration of chlorine gas. Sensor converts the signal in electrode into analog signal.

Nitrate Ion Sensor

The sensor is designed with ion selective electrode. It is a kind of electrochemistry sensor which measures ion activity and concentration in solution using membrane potential. When it touches the solution with ion to be measured, membrane potential will be generated between its membrane and solution. Ion selective electrode is also called membrane electrode. There is a layer of special electrode membrane on the electrode which response to specific ion. The relationship between potential of electrode membrane and ion to be measured compliance with Nernst formula. The circuit of sensor convert potential to analog signal.

Chloride Ion Sensor

The sensor is designed with ion selective electrode. It is a kind of electrochemistry sensor which measures ion activity and concentration in solution using membrane potential. When it touches the solution with ion to be measured, membrane potential will be generated between its membrane and solution. Ion selective electrode is also called membrane electrode. There is a layer of special electrode membrane on the electrode which response to specific ion. The relationship between potential of electrode membrane and ion to be measured compliance with Nernst formula. The circuit of sensor convert potential to analog signal.

Ammonium Ion Sensor

The sensor is designed with ion selective electrode. It is a kind of electrochemistry sensor which measures ion activity and concentration in solution using membrane potential. When it touches the solution with ion to be measured, membrane potential will be generated between its membrane and solution. Ion selective electrode is also called membrane electrode. There is a layer of special electrode membrane on the electrode which response to specific ion. The relationship between potential of electrode membrane and ion to be measured compliance with Nernst formula. The circuit of sensor converts potential to analog signal.