  • SD_S2129-Multi-Range Current Sensor(1757039308613).png

Current Sensor (Multi-Range)

Classification:

SenseDisc

Product Model:

S2129

Grade:

Function Description:

1. Used to measure current in a circuit. 2. Features a three-range selector switch, allowing you to switch measurement ranges with a single click according to experimental requirements.

Share products:

Product Introduction Product Configuration Related Videos Typical case Related Downloads

Name: Current Sensor (Multi-Range)

Scale 1:
1. Range: -20mA to 20mA
2. Accuracy: ±1%
3. Resolution: 0.01mA
4. Internal resistance: 5.1Ω
Scale 2:
1. Range: -200mA to 200mA
2. Accuracy: ±1%
3. Resolution: 0.1mA
4. Internal resistance: 500mΩ
Scale 3:
1. Range: -2A to 2A
2. Accuracy: ±1%
3. Resolution: 0.001A
4. Internal resistance: 50mΩ

Typical Experiments

Ohm's law,

plotting the volt-ampere characteristic curve of a small light bulb,

measuring the electromotive force and internal resistance of a battery,

series and parallel connection of resistors, LC oscillation,

electromagnetic induction,

induced current,

series and parallel connection of capacitors, and charging and discharging, etc.

 

Related Products



Chlorine Gas Sensor

The working principle of Chlorine Gas Sensor is measuring concentration of chlorine by using electrochemistry. The probe consists of electrode and electrolyte. The electrolyte is separated by a selective gas-permeable membrane. The gas diffusing in sensor occurs redox reaction on the surface of electrode. Current is generated in the electrode. The value of current is corresponding to the concentration of chlorine gas. Sensor converts the signal in electrode into analog signal.


Nitrate Ion Sensor

The sensor is designed with ion selective electrode. It is a kind of electrochemistry sensor which measures ion activity and concentration in solution using membrane potential. When it touches the solution with ion to be measured, membrane potential will be generated between its membrane and solution. Ion selective electrode is also called membrane electrode. There is a layer of special electrode membrane on the electrode which response to specific ion. The relationship between potential of electrode membrane and ion to be measured compliance with Nernst formula. The circuit of sensor convert potential to analog signal.


Chloride Ion Sensor

The sensor is designed with ion selective electrode. It is a kind of electrochemistry sensor which measures ion activity and concentration in solution using membrane potential. When it touches the solution with ion to be measured, membrane potential will be generated between its membrane and solution. Ion selective electrode is also called membrane electrode. There is a layer of special electrode membrane on the electrode which response to specific ion. The relationship between potential of electrode membrane and ion to be measured compliance with Nernst formula. The circuit of sensor convert potential to analog signal.


Ammonium Ion Sensor

The sensor is designed with ion selective electrode. It is a kind of electrochemistry sensor which measures ion activity and concentration in solution using membrane potential. When it touches the solution with ion to be measured, membrane potential will be generated between its membrane and solution. Ion selective electrode is also called membrane electrode. There is a layer of special electrode membrane on the electrode which response to specific ion. The relationship between potential of electrode membrane and ion to be measured compliance with Nernst formula. The circuit of sensor converts potential to analog signal.