Voltage Sensor (Multi-Range)
Classification:
SenseDisc
Product Model:
S2128
Grade:
Function Description:
1. Used to measure voltage across circuits and electrical devices. 2. Features a three-range selector switch, allowing you to switch measurement ranges with a single click according to experimental requirements.
Share products:
Name: Voltage Sensor (Multi-Range)
Scale 1:
1. Range: -300mV to 300mV
2. Accuracy: ±1%
3. Resolution: 0.2mV
4. Internal resistance: >1MΩ
Scale 2:
1. Range: -3V to 3V
2. Accuracy: ±1%
3. Resolution: 0.001V
4. Internal resistance: >40kΩ
Scale 3:
1. Range: -30V to 30V
2. Accuracy: ±1%
3. Resolution: 0.02V
4. Internal resistance: >40kΩ
Typical experiments
Explore the relationship between the voltage across an electrical device and the voltage across a power supply in series and parallel circuits,
measure the resistance of a light bulb using the volt-ampere method,
observe the charge and discharge of a capacitor,
study the volt-ampere characteristic curve, measure the resistivity of metals using the volt-ampere method, and measure the electromotive force and internal resistance of batteries and power supplies.
Related Products
CO Sensor is a kind of constant potential electrolytic type sensor. CO and O2 produce charge and form current by redox reaction. The amplitude of current is direct proportional to concentration of CO. We can determine the concentration of CO is high or low by detecting current.
H2 Sensor is a kind of constant potential electrolytic type sensor. H2 and O2 produce charge and form current by redox reaction. The amplitude of current is direct proportional to concentration of hydrogen. We can determine the concentration of hydrogen is high or low by detecting current.
The working principle of NH3 Sensor is measuring concentration of gas by using electrochemistry. The probe consists of electrode and electrolyte. The electrolyte is separated by a selective gas-permeable membrane. The gas diffusing in sensor occurs redox reaction on the surface of electrode. Current is generated in the electrode. The value of current is corresponding to the concentration of gas. Sensor converts the signal in electrode into analog signal.
The working principle of O3 Sensor is measuring concentration of gas by using electrochemistry. The probe consists of electrode and electrolyte. The electrolyte is separated by a selective gas-permeable membrane. The gas diffusing in sensor occurs redox reaction on the surface of electrode. Current is generated in the electrode. The value of current is corresponding to the concentration of gas. Sensor converts the signal in electrode into analog signal.
7F, No.1 Building, Tianan Cyber Park, No.36 Yongfeng Road, Qinhuai District, Nanjing, China. (R&D centre)
No.306 Wenchang Road, Yongyang Street, Lishui Disctric, Nanjing, China. (Manufacturing base)
©COPYRIGHT 2026 Jiangsu SWR Science & Technology Co.,Ltd. ALL RIGHTS RESERVED | SEO