Voltage Sensor (Multi-Range)
Classification:
SenseDisc
Product Model:
S2128
Grade:
Function Description:
1. Used to measure voltage across circuits and electrical devices. 2. Features a three-range selector switch, allowing you to switch measurement ranges with a single click according to experimental requirements.
Share products:
Name: Voltage Sensor (Multi-Range)
Scale 1:
1. Range: -300mV to 300mV
2. Accuracy: ±1%
3. Resolution: 0.2mV
4. Internal resistance: >1MΩ
Scale 2:
1. Range: -3V to 3V
2. Accuracy: ±1%
3. Resolution: 0.001V
4. Internal resistance: >40kΩ
Scale 3:
1. Range: -30V to 30V
2. Accuracy: ±1%
3. Resolution: 0.02V
4. Internal resistance: >40kΩ
Typical experiments
Explore the relationship between the voltage across an electrical device and the voltage across a power supply in series and parallel circuits,
measure the resistance of a light bulb using the volt-ampere method,
observe the charge and discharge of a capacitor,
study the volt-ampere characteristic curve, measure the resistivity of metals using the volt-ampere method, and measure the electromotive force and internal resistance of batteries and power supplies.
Related Products
The working principle of Chlorine Gas Sensor is measuring concentration of chlorine by using electrochemistry. The probe consists of electrode and electrolyte. The electrolyte is separated by a selective gas-permeable membrane. The gas diffusing in sensor occurs redox reaction on the surface of electrode. Current is generated in the electrode. The value of current is corresponding to the concentration of chlorine gas. Sensor converts the signal in electrode into analog signal.
The sensor is designed with ion selective electrode. It is a kind of electrochemistry sensor which measures ion activity and concentration in solution using membrane potential. When it touches the solution with ion to be measured, membrane potential will be generated between its membrane and solution. Ion selective electrode is also called membrane electrode. There is a layer of special electrode membrane on the electrode which response to specific ion. The relationship between potential of electrode membrane and ion to be measured compliance with Nernst formula. The circuit of sensor convert potential to analog signal.
The sensor is designed with ion selective electrode. It is a kind of electrochemistry sensor which measures ion activity and concentration in solution using membrane potential. When it touches the solution with ion to be measured, membrane potential will be generated between its membrane and solution. Ion selective electrode is also called membrane electrode. There is a layer of special electrode membrane on the electrode which response to specific ion. The relationship between potential of electrode membrane and ion to be measured compliance with Nernst formula. The circuit of sensor convert potential to analog signal.
The sensor is designed with ion selective electrode. It is a kind of electrochemistry sensor which measures ion activity and concentration in solution using membrane potential. When it touches the solution with ion to be measured, membrane potential will be generated between its membrane and solution. Ion selective electrode is also called membrane electrode. There is a layer of special electrode membrane on the electrode which response to specific ion. The relationship between potential of electrode membrane and ion to be measured compliance with Nernst formula. The circuit of sensor converts potential to analog signal.