Apparatus for Determining Oxygen Content in Air
Classification:
Chemistry
Product Model:
TP6056
Grade:
Junior high school
Function Description:
Used for measuring oxygen content in air.
Share products:
Configuration:
High voltage power supply, reaction generating device (base, gas cylinder, burning spoon, hole plug, beaker), power cable, banana plug to alligator clip wire
Functions & Applications:
1. Used for measuring oxygen content in air. It can not only observe the burning of red phosphorus, but also monitor the change of oxygen content and pressure in the bottle during the burning of red phosphorus.
2. The use of high-voltage power supply to generate electric spark ignition, the experiment process does not directly contact the burning red phosphorus, effectively reduce the harm of the combustion and its products to the human body, and the experimental safety is high.
3. The whole process of reaction and detection is closed, which effectively reduces the error caused by internal air expansion and leakage caused by heat after red phosphorus combustion and then put into the gas collection cylinder, and the experimental data is more accurate.
4. There is a sensor hole on the gas cylinder, which has good adaptability, and can be used with the oxygen sensor and absolute pressure sensor to display the oxygen content and the pressure change process in the bottle, and real-time data can be presented on Windows, Android, and iOS system terminals.
5. Equipped with special experimental software, preset template. Automatically record data changes in the form of tables and curves, the experimental results are more intuitive and obvious.
Szie: 200mm*100mm*135mm
Weight: 1.223kg
Related Products
The Micro-Voltage Sensor is used to measure voltage within -60mV to 60mV. It amplifies the input voltage in order to measure voltage in micro level.
Milli-Current Sensor is used to measure the current within -20 to 20mA in circuit. When current passes through resistor, it will form a tiny electric potential difference at both ends of the resistor. After circuit amplifying, it can accurately measure the current in circuit.
Microphone collects sound signal using to electret microphone. The microphone consists of dust gauze, shell, vibrating diaphragm, spacer, back plate, copper ring, cavity and PCB. The microphone is formed to a capacitor with vibrating diaphragm, spacer and back plate. There are charge on the plastic vibrating diaphragm. Once it is affected by sound, the diaphragm starts vibrating so that distance between diaphragm and back plate changes. The difference Δd is generated. According to C=εS/4πkd, the capacitance will be changed by ΔC. According to C=Q/V (Q is electric charge quantity), due to the change of ΔC, Q is constant so that voltage will change by ΔV. The sound signal is transfer to electric signal. Sensor circuit transfer the electric signal into analog signal under standard range.
Used to measure the temperature of the surface of the object, gas, non-corrosive acid and alkali liquid.
7F, No.1 Building, Tianan Cyber Park, No.36 Yongfeng Road, Qinhuai District, Nanjing, China. (R&D centre)
No.306 Wenchang Road, Yongyang Street, Lishui Disctric, Nanjing, China. (Manufacturing base)
©COPYRIGHT 2023 Jiangsu SWR Science & Technology Co.,Ltd. ALL RIGHTS RESERVED | SEO